| Product code |
211776 |
211777 |
211778 |
211779 |
| Model |
DF411 |
DF611 |
DH411 |
DH611 |
| System |
Forced convection and ventilation |
| Performance |
Operating temp. range |
Room temp. + 10 to 260deg.C |
Room temp. + 10 to 360deg.C |
| Temp. adjustment accuracy |
±0.1deg.C(at 260deg.C) |
±0.2deg.C(at 360deg.C) |
| Temp. distribution accuracy |
±1.5deg.C(at 260deg.C) |
±2.5deg.C(at 360deg.C) |
| Time to attain max. temp. |
Approx. 60 min. (to 260deg.C) |
Approx. 80 min. (to 360deg.C) |
| Configuration/Functions |
Temp. control system |
PID control with a micro computer |
| Temp. and time setting system |
Digital setting and display with a jog dial |
| Timer display range |
Fixed value operation for 1 min. to 99 hr 59 min. and 100 to 999 hr |
| Operation and manipulation functions |
Auto start, auto stop, fixed value operation |
| Programmed operation (up to 16 segments, repeat operation, gradient operation, etc.) |
| Additional functions |
Actual 24 hr timer function |
| Accumulation timer function (accumulation up to 49,999 hrs) |
| Calibration offset function |
| Clock display (preset time display) |
| Sensor |
Double K-thermocouple |
| Heater |
Stainless pipe heater with a fan |
| Nominal heater capacity |
2.1kW |
3.0kW |
2.7kW |
3.75kW |
| Blower fan (motor) |
Axial flow fan (capacitor motor: 20W) |
| Cable port |
I.D. 30 mm (rear) |
| Heat insulator |
Glass wool |
Ceramic fiber |
| Other additional mechanism |
Exhaust damper (manual) |
| Safety device |
Self diagnostic function (temp. sensor error, heater disconnection, SSR short-circuit, automatic overheat prevention function), key lock, door switch, electric leakage breaker, control box switch |
| Standards |
Internal dimensions (mm)(WxDxH) |
450×450×450 |
600×600×600 |
450×450×450 |
600×600×600 |
| External dimensions (mm)(WxDxH) |
1,050×630×850 |
1,200×780×1000 |
1,050×630×850 |
1,200×780×1000 |
| Internal volume |
91L |
216L |
91L |
216L |
| Withstand load of shelf board |
30 kg/unit |
| No.of shelf stages/peg pitch |
9 stages/45 mm |
9 stages/60 mm |
9 stages/45 mm |
9 stages/60 mm |
| PS (50/60) Hz rated current |
Single phase AC200V 11A (15A) |
Single phase AC200V 16A (20A) |
Single phase AC200V 14A (20A) |
Single phase AC200V 20A (30A) |
| Weight |
Approx. 78 kg |
Approx. 109 kg |
Approx. 78 kg |
Approx. 109 kg |
| Accessories |
Shelf |
Stainless wire |
| 2 |
3 |
2 |
3 |
| Shelf support |
4 |
6 |
4 |
6 |
Optional
items |
| Remark |
Description |
Model No. |
Product Code |
| ○ |
Stand OP42, for DF/DH411(without caster) |
DF/DH Series |
415460 |
| ○ |
Stand OP62, for DF/DH611(without caster) |
DF/DH Series |
415462 |
| ○ |
Stand OP45, for DF/DH411(with front side caster with stopper) |
DF/DH Series |
415461 |
| ○ |
Stand OP65, for DF/DH611(with front side caster with stopper) |
DF/DH Series |
415463 |
| |
Stacking support |
DF/DH Series |
211065 |
| |
Stainless wire shelf (with support 2 pcs., loading up to 30 kg/shelf) for DF/DH411 |
DF/DH Series |
211063 |
| |
Stainless wire shelf (with support 2 pcs., loading up to 30 kg/shelf) for DF/DH611 |
DF/DH Series |
211064 |
| |
Stainless punching metal shelf (loading up to 15kg/shelf) for DF/DH411 |
DF/DH Series |
211098 |
| |
Stainless punching metal shelf (loading up to 15kg/shelf) for DF/DH611 |
DF/DH Series |
211099 |
| ● |
Wind velocity changeable function |
DF/DH Series |
281060 |
| |
Fan Revolution Changeable Range; |
|
|
| |
50Hz: approx. 450-1,350rpm |
|
|
| |
60HZ: approx. 450-1,550rpm |
|
|
| ● |
External communication adapter |
DF/DH Series |
281061 |
| ● |
Abnormal alarm display |
DF/DH Series |
281062 |
| ● |
Emergency stop switch |
DF/DH Series |
281063 |
| ● |
Recorder (6 points type) |
DF/DH Series |
281064 |
| ● |
Additional sensor (sheath sensor) |
DF/DH Series |
281065 |
| ● |
Manual recovery function from blackout |
DF/DH Series |
281066 |
| ● |
Automatic damper : 5 steps : 5%-25%-50%-75%-100% |
DF/DH Series |
281067 |
| ● |
Exhaust duct (80mm dia) |
DF/DH Series |
281068 |
| ● |
Flange for exhaust port |
DF/DH Series |
281069 |
| ● |
Observation window (for DF Type only) |
DF/DH Series |
281070 |
| ● |
Wind velocity changeable function |
DF/DH Series |
281071 |
| ● |
Power cord, 5m. |
DF/DH Series |
281072 |
| ● |
Power plug |
DF/DH Series |
281074 |
| ● |
Cable port, 25mm dia |
DF/DH Series |
281075 |
| ● |
Cable port, 50mm dia |
DF/DH Series |
281076 |
|
Note:
1.
The item marked " ● " in the column of "Remark" shall be ordered together with the main unit.
2. The transportation cost will not be required if the order is together with main unit except the item marked "○".
In case you order the item marked "○" together with the main unit, please ask Yamato to obtain the correct transportation cost. |