| Vertical type LCD Batch Aging System |
| YY-307WAV-R |
| Operating Temperature Range |
| 40deg.C to 70deg.C |
| Temperature Control Accuracy |
| ±1.0deg.C (at 80deg.C) |
| Temperature Uniformity |
| ±5.0deg.C (at 80deg.C) |
|
Equipment Summary
This system is the vertical type LCD module aging chamber used for quality control
and quality assurance processes. The system is composed of a control panel and
thermostatic chambers with built-in LCD module driver circuits.
To manage a variety of LCD modules, additional computerized control systems are
available upon request as options.
Feature
- Front drawer type loading system for setting LCD modules,facilitating feeding, Discharging and inspection modules.
- The aging system in designed for saving space and maximizing workability.
- Equipped with complete safety devices, Earth leakage breaker, blower, heater burn out, Upper limit temperature alarm, external indicator lamp, heat sensor etc.
|

|
| |
 |
| Specifications |
| Model |
YY-307WAV-R |
Performance |
| Circulation method |
Forced hot air circulation with heating
control of the heater |
| Operating temperature range |
40deg.C-80deg.C |
| Temperature control accuracy |
± 1.0deg.C(at 80deg.C) |
| Temperature uniformity |
± 5deg.C(at 80deg.C) |
Configuration |
| External material |
Cold-rolled steel plate, Melamine resin
backing finish |
| Internal material |
Stainless steel plate |
| Heat insulating material |
Glass wool |
| Heater |
Stainless pipe heater |
| Fan |
Aluminum sirocco fan with motor |
Instruments |
| Temperature controller |
Electronic temperature programmable controller
PID control, Digital setting and Digital indication |
| Timer |
Digital setting system, Arbitrarily set
with in the range from 0.1s to 9,9990H(Provided with auto
start/
stop function) |
| Temperature sensor |
K-type thermocouple, double-sensor(One
sensor is provided for overheat protector) |
Safety features |
| Short circuit breaker |
Protects the machine from leakage |
| Overheating protection |
At overheat, the power supply for the
heaters shall be cut off |
| Temperature upper limit alarm |
Excessive temperature rise prevention
circuit incorporated protected in temperature
controller.
When the temperature has reached the specified upper limit, the power supply
for the heaters shall be cut
off. |
| Protecting circuit for fan motor |
When the motor is overloaded, the power
supply for the heaters and that for the motor shall be cut
off.
|
| Error indication |
When any of the error has occurred, the
alarm buzzer shall sound and each warning shall be displayed
on
the operation panel. |
Required Utility |
| Electric power supply |
AC200/208/220 V Single phase 50/60Hz |
|
| |
HORIZONTAL
TYPE AGING CHAMBER |
|
|
Feature
- Able to aging many panels at one time by using a panel rack
- With
special contact system, panel rack and chamber have smooth
and quick connection and easy setting
- Able to check panels
visually through the wide view door.
|
|
| |
SEE-THROUGH
TYPE AGING CHAMBER |
|
|
Feature
- Able to check panels over aging
- Easy to open and close with
sliding door
- No need spaces of opening and closing doors
- Easy
setting panels
|
|
| Contact
us |
| Rerurn |
| IN-LINE TYPE LCM/TV
AGING SYSTEM |
| Equipment Summary |
| This in-line aging system is designed for final inspection in
the LCD module process. The system is to find defects of each LCD
module in hot air circumstance. For this inspection, the system
allows LCD modules outputting pattern all the time.The whole system
is controlled by PLC. |
ROTARY RACK TYPE
|
STACKER CLANE TYPE
|
FPD
RACKY (CART TYPE) WITH AGV
|
VERTICAL TYPE (SEMI IN-INLINE)
|
| Contact
us |
| Rerurn |
Request for documents
Return to Home
Copyright(c) 1998 YAMATO SCIENTIFIC CO.,LTD. ALL rights
reserved For more information,call 0120-405-525 (Free dial) E-mail:english-website@yamato-net.co.jp
|