Shaking Incubators
BT100/200/300
Model
100 200 300
Temp. Control Accuracy
Room Temp. +5deg.C to +80deg.C
Temp. Distribution Accuracy
±0.1
Accommodation Capacity
(Test tube, dia.16.5mm)
130 pcs. 169 pcs. 260 pcs.

The BT units are constant temperature water baths that shake.

They feature an easy-to-use and flexible inner tank and integrated vibrating design. They also incorporate a thermostat that enables fixed operation and comprehensive safety features..

  • The vibration range varies extends from 10 to 44mm and can be freely changed, while the oscillation frequency ranges from 20 to 160 times per minute,allowing for non-incremental speed transition. settings are input using a controller with a digital display.
  • Settings for the temperature and timer can be easily input using the up and down keys, and the settings appear on a digital display.
Control Panel
Control Panel BT100/200/300

BT100/200

Rack for Test Tube
 
BT100 Rack for Test Tube BT300 Rack for Test Tube
BT200 Rack for Test Tube  

Specifications
Model BT100 BT200 BT300
* Performance
Method Reciprocating shaking system, Stirring by pump
Operating temp. range Room temp. +5deg.C to 80deg.C
Temperature control accuracy ±0.02deg.C to 0.08deg.C
Temperature distribution accuracy ±0.1deg.C
Temperature rising time Approx. 95 min. Approx. 70 min. Approx. 120 min.
Shaking frequency 20 to 160 times/min.
Shaking width 10 to 40mm (adjustable)
* Components
Temp. Controller PID control by microprocessor
Temp. Sensor Pt resistance thermometer (double sensor)
Temp setting method Digital setting
Temp display method Digital display
Overheat protector ON/OFF control by microprocessor
Overheat protect setting method Digital setting
Overheat protect sensor K-thermocouple (double sensor)
Heater Copper pipe heater (nickel plated)
1.2kW 1.9kW 2.5kW
Stirring System Magnet pump
6W 10W 10W
Shaker Gear motor
25W 40W 40W
Shaking speed setting system Analog setting
Shaking speed display system Digital display
Timer 1 min. to 999 hr. 50 min.
Digital display, Quick automatic start/stop
* Safe Device
Safety countermeasures Self-diagnosis function(Heater defective, Sensor defective, Set value abnormal, SSR short circuit and Overheat protector) Warning buzzer and alarm lump, Over current, short circuit breaker, Heater no-load operation prevention device and overheat protector.
* Standard
Container flame number, Test tube Dia : 16.5mm, Length : 150 to 200mm(JIS)
130 pcs. 169 pcs. 260 pcs.
Flask Round, Erlenmeyer flask 100/300/500ml
12/5/3pcs. 16/9/6pcs. 24/10/6pcs.
Material (Interior) Stainless steel
Internal dimensions(W×D×Hmm) 302×350×250 372×350×250 532×350×250
External dimensions(W×D×Hmm) 579×414×325 649×414×325 809×414×325
Tank Capacity 19L 23L 34L
Power source 50/60Hz AC100V/230V, Single phase,
14A/6.5A
AC100V/230V, Single phase,
21A/10A
AC200V/230V, Single phase,
14.5A/14A
Weight Approx. 27kg Approx. 40kg Approx. 48kg
* Accessories
Shaking Rack 1 pc. 1 pc. 2 pc.
(Dimensions W×D×Hmm) 290×220×170 290×290×170 290×220×170
Spring Pitch 20mm (both length and width)
Optional items
Description Model No. Product Code
Lid for BT100  BT Series 221380
Lid for BT200 BT Series 221381
Lid for BT300 BT Series 221382
Top View (Optional accessories)

Contact us

Request reference material

Request for documents

Return to Home


Copyright(c) 1998 YAMATO SCIENTIFIC CO.,LTD. ALL rights reserved For more information,call 0120-405-525 (Free dial) E-mail:english-website@yamato-net.co.jp